Uploaded image for project: 'Bug Archive'
  1. Bug Archive
  2. BUGARCHIVE-6626

ORA U6.x: The compatibility driver setting does not allow larger step sizes

    XMLWordPrintable

    Details

    • Type: Maintenance
    • Status: Fixed (View Workflow)
    • Resolution: Unresolved
    • Labels:
      None
    • Old bug number:
      28303
    • Patch version:
      D611

      Description

      Uniface 8 only.
      When the Oracle driver setting (usys$ora_params) u36_compatibility or
      u4_compatibility is set then the step size setting is not working in case it
      has a value > 19. The exact number depends on the size of the fixed fields.

      For example, when setting the step size to 50 (usys$ora_params =
      u36_compatibility, step size 50) then Uniface will retrieve the data in steps
      of 19 (and not as expected 50). In case the step size is <= 19 then the driver
      will use the specified step size.

      This problem can only be replicated in Uniface version 8 and does not occur in
      version 9.

        Attachments